Product details
Danfoss KP5 High Pressure Switch | Automatic Reset | 060-117191
Product Description: The KP5 (060-117191) is engineered to protect the high-pressure side of refrigeration compressors. In the UAE’s demanding cooling market—where rooftop units and plant rooms often face extreme heat—the KP5 acts as a fail-safe to prevent system over-pressurization. This model features an Automatic Reset and a regulation range of 8 to 32 bar. Its high-load SPDT contact system and vibration-resistant construction ensure that it provides reliable switching and a long service life, even when mounted on high-vibration compressor frames in Dubai’s industrial zones.
Key Features & Benefits:
- High-Pressure Cutout: Effectively protects compressors from damage caused by high discharge pressures, such as from a failed condenser fan or dirty coils.
- Automatic Reset: Resets the circuit automatically once the pressure drops below the differential setting, allowing for unmanned operation in UAE facilities.
- Vibration Resistance: Specially designed to maintain setpoint accuracy despite the heavy mechanical resonance common in large-scale HVAC systems.
- Short Contact Bounce: Minimizes electrical arcing and wear, extending the life of the switch and the connected electrical components.
- Universal Refrigerant Use: Suitable for all common fluorinated refrigerants (HCFC and non-flammable HFC) used across the Middle East.
Technical Specifications:
| Specifications | Value |
| Manufacturer | Danfoss |
| Series | KP5 |
| Code Number | 060-117191 |
| Regulation Range | 8.00 – 32.00 bar |
| Differential (Δp) | 1.80 – 6.00 bar |
| Contact Function | SPDT |
| Reset Function | Automatic |
| Pressure Connection | 1/4 in Flare (6 mm) |
| Enclosure Rating | IP30 |
Export to Sheets
FAQs:
- Q: Is the 32-bar range sufficient for R410A systems in the UAE?
- A: Yes, the KP5 is frequently used for R410A applications, though for very high-pressure safety requirements, the KP6 series is sometimes preferred.
- Q: Can this be used as a fan cycling switch in Dubai?
- A: Yes, due to its SPDT contact and adjustable differential, it is often used to cycle condenser fans to maintain stable head pressure.
- Q: What is the benefit of the flare connection?
- A: The 1/4-inch flare connection allows for easy, leak-proof installation using standard refrigeration hoses or copper capillary lines commonly found in UAE workshops.

![018F6801 - Solenoid coil, BG230AS, Terminal box, Supply voltage [V] AC: 220 - 230, Multi pack Danfoss](https://haste-uae.com/wp-content/uploads/2026/02/Untitled-design-6-4-400x400.png)
![018F6251 - Solenoid coil, BF230AS, Cable, 1.000 m, Supply voltage [V] AC: 220 - 230, Multi pack Danfoss](https://haste-uae.com/wp-content/uploads/2026/02/Untitled-design-3-8-400x400.png)