Product details
Danfoss EVR 10 Solenoid Valve | 1/2 in Solder ODF | 032L1217
Product Description: The EVR 10 (032L1217) is engineered to withstand the demanding conditions of the Middle Eastern cooling market. In the UAE—where refrigeration racks in supermarkets and split AC systems in commercial buildings run at high capacities—the EVR 10 provides reliable flow control with a focus on leak-tightness. This model features $1/2$ inch solder (ODF) connections, ensuring a permanent and secure fit in high-vibration environments. Its “Normally Closed” function means the valve remains shut when de-energized, preventing refrigerant migration and protecting the compressor during off-cycles.
Key Features & Benefits:
- Reliable NC Function: Securely shuts off refrigerant flow when power is removed, essential for system safety and pump-down cycles in UAE installations.
- Versatile Application: Optimized for use in liquid, suction, and hot gas lines with all common fluorinated refrigerants (HCFC/HFC/Non-flammable HFO).
- Durable Solder Connections: The $1/2$ inch ODF solder ends provide a robust, leak-proof interface suitable for the high-pressure environments of Dubai and Abu Dhabi.
- Compact Design: Allows for easy installation in tight machinery spaces and refrigeration racks.
- High-Ambient Performance: Built to operate reliably even in the high temperatures typical of UAE mechanical rooms.
Technical Specifications:
| Specifications | Value |
| Manufacturer | Danfoss |
| Series | EVR 10 (v2) |
| Code Number | 032L1217 |
| Function | Normally Closed (NC) |
| Connection Size | $1/2$ in (Solder, ODF) |
| Max. Working Pressure | 45.2 bar (655 psig) |
| Temperature Range | -40°C to 105°C |
| Media Compatibility | R410A, R134a, R404A, R407C, R507, etc. |
FAQs:
- Q: Is the coil included with the 032L1217 in the UAE?
- A: No, this code is for the valve body only. You will need to pair it with a Danfoss clip-on coil (110V, 230V, or 24V) depending on your electrical setup.
- Q: Can this valve be used with the latest low-GWP refrigerants?
- A: Yes, the newer EVR v2 series is compatible with a wide range of modern refrigerants used in the UAE, including some R452A and R448A blends.
- Q: Does it require a minimum pressure drop to open?
- A: Yes, as a servo-operated valve, the EVR 10 requires a minimum pressure differential (typically 0.05 bar) to open and stay open.



![018F6251 - Solenoid coil, BF230AS, Cable, 1.000 m, Supply voltage [V] AC: 220 - 230, Multi pack Danfoss](https://haste-uae.com/wp-content/uploads/2026/02/Untitled-design-3-8-400x400.png)

![018F6701 - Solenoid coil, BE230AS, Terminal box, Supply voltage [V] AC: 220 - 230, Multi pack Danfoss](https://haste-uae.com/wp-content/uploads/2026/02/Untitled-design-6-3-400x400.png)
![018F6801 - Solenoid coil, BG230AS, Terminal box, Supply voltage [V] AC: 220 - 230, Multi pack Danfoss](https://haste-uae.com/wp-content/uploads/2026/02/Untitled-design-6-4-400x400.png)