Danfoss EVR 6 Solenoid Valve | 3/8 in Solder ODF | 032L1212
Product Description: The EVR 6 (032L1212) is engineered for reliability in the intense cooling environments of the Middle East. In the UAE—where precision control in supermarket display cases and small-scale cold storage is vital—the EVR 6 ensures tight refrigerant shut-off. This model features 3/8 inch solder (ODF) connections, providing a permanent, leak-proof joint that is highly resistant to the vibrations common in rooftop condensing units and refrigeration racks. Its “Normally Closed” configuration ensures that the valve remains shut when de-energized, preventing refrigerant migration and protecting the compressor from liquid slugging during off-cycles.
Key Features & Benefits:
- Proven Reliability: The EVR v2 platform is built for a long service life with minimal maintenance in high-ambient temperature regions like Dubai and Abu Dhabi.
- Leak-Proof Solder Ends: The 3/8 in ODF connections ensure a secure, permanent fit, essential for maintaining system charge in the harsh UAE climate.
- Versatile Media Use: Fully compatible with all common fluorinated refrigerants (HCFC, HFC, and non-flammable HFO), including R410A, R134a, and R404A.
- Compact Industrial Design: Its small footprint allows for easy installation in tight spaces within commercial AC units or refrigeration equipment.
- High Working Pressure: Rated for up to 45.2 bar, making it suitable for high-pressure R410A and R32 applications common in modern UAE HVAC projects.
Technical Specifications:
| Specifications | Value |
| Manufacturer | Danfoss |
| Series | EVR 6 (v2) |
| Code Number | 032L1212 |
| Function | Normally Closed (NC) |
| Connection Size | 3/8 in (Solder, ODF) |
| Max. Working Pressure | 45.2 bar (655 psig) |
| Flow Capacity ($K_v$) | $0.800\ m^3/h$ |
| Media Temperature | -40°C to 105°C |
FAQs:
- Q: Can I use the 032L1212 for hot gas defrosting in Dubai?
- A: Yes, the valve is rated for temperatures up to 105°C, making it suitable for hot gas bypass and defrost applications.
- Q: Is the coil included with the valve body?
- A: No, this code is for the valve body only. In the UAE, you typically pair it with a Danfoss 10W or 12W Clip-on coil (available in 24V, 110V, or 230V).
- Q: Does it require a minimum pressure drop to operate?
- A: Yes, as a servo-operated valve, the EVR 6 requires a minimum differential pressure (typically 0.05 bar) to open and remain open.