Product details
Danfoss DML 164 Hermetic Filter Drier | 1/2 in Flare | 023Z5044
Product Description: The DML 164 (023Z5044) is engineered to provide the highest level of drying capacity. In the UAE’s high-humidity coastal environments, moisture in the refrigeration circuit can lead to acid formation and compressor failure. The DML series solves this with a solid core of 100% 3Å molecular sieve, which adsorbs water without depleting the essential oil additives found in HFC refrigerants like R134a, R404A, and R410A. This model features a 16 cubic inch core and 1/2 inch flare connections, making it a versatile choice for both new installations and field repairs in Dubai’s commercial cooling and residential HVAC sectors.
Key Features & Benefits:
- 100% Molecular Sieve Core: Provides maximum moisture adsorption capacity, ensuring the system remains dry even in the challenging Middle Eastern climate.
- No Oil Additive Depletion: Because it contains no activated alumina, it protects the chemical integrity of POE and PAG oils used in modern HFC systems.
- High Dirt Retention: Features a 25 $\mu$m filter that effectively traps solid particles with minimal pressure drop, safeguarding expansion valves and capillary tubes.
- Corrosion Resistant Shell: The steel housing is finished with a powder-painted coating, offering durability against the saline air and humid conditions of the UAE.
- Bi-flow Compatibility: Can be installed in any orientation (following the flow arrow), allowing for flexible installation in tight mechanical spaces.
Technical Specifications:
| Specifications | Value |
| Manufacturer | Danfoss |
| Series | ELIMINATOR® DML |
| Code Number | 023Z5044 (DML 164) |
| Core Size | 16 cu.in. |
| Connection Size | 1/2 in (Flare / SAE) |
| Body Material | Steel |
| Max. Working Pressure | 46 bar (667 psig) |
| Temperature Range | -40°C to 70°C |
| Refrigerants | R410A, R134a, R404A, R407C, R32, etc. |
FAQs:
- Q: Why use DML instead of DCL in the UAE?
- A: DML (100% molecular sieve) is recommended for systems using HFC/HFO refrigerants and POE/PAG oils where high moisture capacity is the priority. DCL is better for older systems using mineral oil that require acid adsorption.
- Q: Does the 023Z5044 handle R410A high pressures?
- A: Yes, it is rated for a maximum working pressure of 46 bar (667 psig), making it fully compatible with R410A systems common in Dubai.
- Q: Can this filter drier be cleaned and reused?
- A: No, this is a hermetic (sealed) unit. Once it is saturated or the system is opened for major repairs, it must be replaced to ensure system purity.




![018F6732 - Solenoid coil, BE230CS, Terminal box, Supply voltage [V] AC: 220 - 230, Multi pack Danfoss](https://haste-uae.com/wp-content/uploads/2026/02/Untitled-design-6-4-400x400.png)