Product details
Danfoss DCL 163 Hermetic Filter Drier | 3/8 in Flare | 023Z500891
Product Description: The DCL 163 (023Z500891) is engineered for systems that require a high reserve of adsorption capacity. In the UAE—where cooling equipment often faces extreme thermal loads—the risk of refrigerant breakdown and subsequent acid formation is elevated. The DCL’s solid core, composed of 80% molecular sieve and 20% activated alumina, provides a dual-action defense that removes moisture and neutralizes acids, thereby protecting the compressor motor from burnout. The 3/8 inch SAE flare connections are a standard in the UAE market, allowing for reliable mechanical joints and easy replacement during routine maintenance in Dubai and Abu Dhabi.
Key Features & Benefits:
- High Adsorption Capacity: The 16 cu.in. core size provides a large surface area for capturing contaminants, extending the service interval in humid UAE environments.
- Dual Protection: Effectively manages both moisture and acid levels, critical for system longevity in high-ambient temperature regions.
- Convenient Flare Connections: 3/8 in flare ends allow for fast installation and field replacement without the need for brazing torches.
- High Working Pressure: Rated for up to 46 bar (667 psig), making it fully compatible with R410A, R32, and other high-pressure refrigerants.
- Superior Filtration: A 25 $\mu$m internal filter traps solid particles, protecting expansion valves and sensitive components from clogging.
Technical Specifications:
| Specifications | Value |
| Manufacturer | Danfoss |
| Series | ELIMINATOR® DCL |
| Code Number | 023Z500891 (DCL 163) |
| Core Size | 16 cu.in. (250 ml) |
| Connection Size | 3/8 in (Flare / SAE) |
| Shell Material | Steel |
| Max. Working Pressure | 46 bar (667 psig) |
| Media Temperature | -40°C to 70°C |
FAQs:
- Q: When should I choose the DCL 163 over the DCL 083?
- A: Use the DCL 163 (16 cu.in.) for larger systems or applications where you want an extra safety margin for moisture and acid removal in the UAE’s heat.
- Q: Is this drier compatible with POE oil systems?
- A: Yes, the DCL series is fully compatible with HFC refrigerants and the POE/PAG oils used in modern HVAC equipment.
- Q: Does the direction of installation matter?
- A: Yes, filter driers are unidirectional. Ensure the flow arrow on the label points toward the expansion device.



![018F6801 - Solenoid coil, BG230AS, Terminal box, Supply voltage [V] AC: 220 - 230, Multi pack Danfoss](https://haste-uae.com/wp-content/uploads/2026/02/Untitled-design-6-4-400x400.png)