Product details
Danfoss AKS 3000 Pressure Transmitter | 0 to 25 bar (0 to 362.5 psi) | 4-20 mA Output |
Product Description:
The Danfoss AKS 3000 (060G1041) is specifically engineered to provide consistent and reliable pressure data in heavy-duty industrial environments. With a measuring range of 0 to 25 bar, it is ideally suited for discharge pressure monitoring in large-scale air conditioning and refrigeration systems across the UAE. Built to withstand the harsh reality of industrial plant rooms, this transmitter features advanced technology that protects against liquid hammer and pressure surges. Its 4-20 mA current output ensures signal integrity over long distances, making it perfect for the massive facility layouts found in Dubai. Encased in a hermetically sealed stainless steel body, it remains resilient against the extreme thermal fluctuations and corrosive humidity typical of the Middle East.
Key Features & Benefits:
- Engineered for High-Side Pressure: 0 to 25 bar range is optimized for discharge monitoring of R134a, R404A, and R407C systems in the UAE.
- Advanced Pulse Protection: Designed to absorb pressure peaks and vibrations, ensuring long-term sensor life in Dubai’s industrial sites.
- Stable 4-20 mA Signal: High immunity to electrical noise, essential when installed near large VFDs and heavy machinery.
- Hermetic Stainless Steel Housing: Provides ultimate protection against moisture ingress and the salty air of the UAE coastline.
- Full Controller Compatibility: Seamlessly integrates with Danfoss ADAP-KOOL systems and all major industrial PLC platforms in Dubai.
Technical Specifications :
| Specifications | Value |
| Manufacturer | Danfoss |
| Product Model | AKS 3000 |
| Code Number | 060G1041 |
| Pressure Range | 0.00 bar – 25.00 bar (0 – 362.50 psi) |
| Output Signal | 4 – 20 mA (2-wire) |
| Supply Voltage | 10V to 30V DC |
| Pressure Connection | G 1/4 A |
| Operating Temperature | -40°C to +85°C |
FAQs:
- Q: Why should I choose AKS 3000 instead of AKS 33 for my project in Dubai?
- A: Choose the AKS 3000 for systems with high vibration or potential for liquid hammer, as it offers a more robust internal sensing element.
- Q: Is the 060G1041 compatible with R134a chillers?
- A: Yes, the 25-bar range is the industry standard for R134a high-side monitoring in the UAE climate.
- Q: Does it require a special cable for the 4-20 mA signal?
- A: A standard shielded 2-wire cable is recommended to maintain the best signal accuracy across large Dubai industrial complexes.