Product details
Danfoss TGE Thermostatic Expansion Valve | R22 & R407C | 067N2006
Product Description: The 067N2006 is engineered for reliability in the UAE’s demanding high-ambient conditions. In the region’s intensive cooling market, this valve is a trusted component for rooftop units and small-to-medium water chillers in Dubai and Abu Dhabi. It features a balanced port design, which is essential for Middle Eastern operations; it ensures that the valve maintains stable superheat control even when condensing pressures fluctuate significantly due to the extreme summer heat. The hermetic, all-laser-welded construction eliminates gaskets and mechanical joints, providing a leak-proof and maintenance-free solution for high-vibration commercial installations.
Key Features & Benefits:
- Dual Refrigerant Compatibility: Optimized for both R22 and R407C, providing a versatile solution for maintenance and retrofitting in the UAE.
- Balanced Port Performance: Guarantees stable refrigerant flow despite the wide fluctuations in ambient temperature and head pressure common in the UAE.
- Leak-Proof Hermetic Design: All-welded construction ensures maximum system integrity and reduces refrigerant recharge costs for UAE building owners.
- Corrosion Resistant: Built with a stainless steel power element to withstand the humid and saline air found in UAE coastal environments.
- Bi-metal Solder Connections: Simplifies the brazing process for UAE technicians, ensuring a safe and reliable installation.
Technical Specifications:
| Specifications | Value |
| Manufacturer | Danfoss |
| Series | TGE |
| Code Number | 067N2006 |
| Refrigerants | R22, R407C |
| Inlet/Outlet Connection | 1/2 in x 5/8 in Solder |
| Static Superheat (SS) | Adjustable |
| Max. Working Pressure | 28.0 bar (400 psig) |
| Body Material | Brass with Stainless Steel power element |
FAQs:
- Q: Can the 067N2006 be used for R22-to-R407C retrofits in Dubai?
- A: Yes, it is fully rated for both, making it an ideal choice for UAE facility managers upgrading their cooling infrastructure.
- Q: Why is the “Balanced Port” design essential for Abu Dhabi summers?
- A: It prevents the valve from “hunting” (unstable operation) when outdoor temperatures are extremely high, ensuring consistent cooling performance.
- Q: Does this valve require regular maintenance in the UAE?
- A: No. Its hermetic, all-welded design makes it maintenance-free. If it fails, the entire unit is replaced to ensure system security.




![018F6701 - Solenoid coil, BE230AS, Terminal box, Supply voltage [V] AC: 220 - 230, Multi pack Danfoss](https://haste-uae.com/wp-content/uploads/2026/02/Untitled-design-6-3-400x400.png)